Ticket #548 (new defect)

Opened 5 years ago

ewthresh has possible problem with uninitiailized stations for group triggers

Reported by: paulf Owned by: somebody
Priority: major Milestone: All Platforms
Component: ALL modules Version: 7.9
Keywords: Cc:

Description

Elmar Rothert of Q-con reports:

when testing the modified ewthresh module with traffic light system warning and alarm sound, I discovered a serious problem: everything works fine, if all stations defined in the .d file are sending data. If a station is NOT sending data, the module still remembers the last value (or takes an arbitrary value if the stations has never sent any data yet) and uses this for coincident threshold exceedance comparison.

Note: See TracTickets for help on using tickets.