Changeset 7933


Ignore:
Timestamp:
03/14/19 16:11:13 (9 days ago)
Author:
chad
Message:

ew2ringserver: add log message when retrying compression with Steim-1

File:
1 edited

Legend:

Unmodified
Added
Removed
  • trunk/src/data_exchange/ew2ringserver/ew2ringserver.c

    r7932 r7933  
    122122static unsigned char TypeTracebuf2; 
    123123 
    124 /* A non-official data encoding for "Steim-2 then Steim1" logic */ 
     124/* A non-official data encoding for "Steim-2 then Steim-1" logic */ 
    125125#define DYNAMIC_STEIM21 -11 
    126126 
     
    12131213           int32encoding == DYNAMIC_STEIM21) 
    12141214      { 
     1215        logit ("et", "Failed to compress data with Steim-2 %s_%s_%s_%s, trying Steim-1\n", 
     1216               mst->network, mst->station, mst->location, mst->channel); 
     1217 
    12151218        trpackedrecords = mst_pack (mst, sendrecord, handlerdata, 512, 
    12161219                                    DE_STEIM1, 1, NULL, flushflag, 
     
    12661269                   int32encoding == DYNAMIC_STEIM21) 
    12671270              { 
     1271                logit ("et", "Failed to compress data with Steim-2 %s_%s_%s_%s, trying Steim-1\n", 
     1272                       mst->network, mst->station, mst->location, mst->channel); 
     1273 
    12681274                trpackedrecords = mst_pack (mst, sendrecord, handlerdata, 512, 
    12691275                                            DE_STEIM1, 1, NULL, flushflag, 